{"id":10486,"date":"2022-07-02T13:05:11","date_gmt":"2022-07-02T13:05:11","guid":{"rendered":"https:\/\/amengineering.am\/product\/nvct-700-12-sp1v\/"},"modified":"2022-07-13T14:24:28","modified_gmt":"2022-07-13T14:24:28","slug":"nvct-700-12-sp1v","status":"publish","type":"product","link":"https:\/\/amengineering.am\/hy\/product\/nvct-700-12-sp1v\/","title":{"rendered":"NVCT.700-12\/SP1V"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"10486\" class=\"elementor elementor-10486\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-06c530a elementor-section-boxed elementor-section-height-default elementor-section-height-default wd-section-disabled\" data-id=\"06c530a\" data-element_type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-52a18ac\" data-id=\"52a18ac\" data-element_type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-46dad62 elementor-widget elementor-widget-wd_text_block\" data-id=\"46dad62\" data-element_type=\"widget\" data-widget_type=\"wd_text_block.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"wd-text-block reset-last-child text-left\">\n\t\t\t\n\t\t\t<table><tbody><tr><td><p><span style=\"font-weight: 400;\">Model No.<\/span><\/p><\/td><td><p><span style=\"font-weight: 400;\">NCV1-1000V\/SP1<\/span><\/p><\/td><\/tr><tr><td><p><span style=\"font-weight: 400;\">Usage<\/span><\/p><\/td><td><p><span style=\"font-weight: 400;\">Level Sensor<\/span><\/p><\/td><\/tr><tr><td><p><span style=\"font-weight: 400;\">Output<\/span><\/p><\/td><td><p><span style=\"font-weight: 400;\">Switching Transducer<\/span><\/p><\/td><\/tr><tr><td><p><span style=\"font-weight: 400;\">Brand Name<\/span><\/p><\/td><td><p><span style=\"font-weight: 400;\">CSR<\/span><\/p><\/td><\/tr><tr><td><p><span style=\"font-weight: 400;\">Theory<\/span><\/p><\/td><td><p><span style=\"font-weight: 400;\">Hall Sensor<\/span><\/p><\/td><\/tr><tr><td><p><span style=\"font-weight: 400;\">Primary nominal voltage<\/span><\/p><\/td><td><p><span style=\"font-weight: 400;\">1000V<\/span><\/p><\/td><\/tr><\/tbody><\/table><div><br \/>1. Primary normal voltage VPN: 700V r.m.s<br \/>2. Primary voltage, measuring range VP: 0~+\/-1000V<br \/>3. Conversion ratio: 1000V\/10V<br \/>4. Secondary nomina<br \/><br \/><\/div><div class=\"productdescription\"><p><strong>NCV1-1000V\/SP1 Voltage Transducer<\/strong><\/p><p><strong>Applications<\/strong>:\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0<\/p><p>For the electronic measurement of voltages: AC, DC IMPL.,etc.,with galvanic isolation between the primary (high voltage) and the secondary (electronic) circuits.<\/p><p><strong>Main technical data:<\/strong><\/p><p>1. Primary normal voltage V<sub>PN<\/sub>: 700V r.m.s<\/p><p>2. Primary voltage, measuring range V<sub>P<\/sub>: 0~+\/-1000V<\/p><p>3. Conversion ratio: 1000V\/10V<\/p><p>4. Secondary nominal output: 7V<\/p><p>5. Load resistance: more than 3000 ohm<\/p><p>6. Supply voltage(+\/-5%): +\/-15V<\/p><p>7. Current consumption: 30mA(@\u00b115V)+ Secondary output voltage\/ load resistance\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0<\/p><p>8. Isolation test: Between the primary circuit and the secondary circuit(+.-.M.0V): 6kVrms\/50Hz\/1min<\/p><p><strong>Accuracy \u2013 Dynamic performance data:<\/strong><\/p><p>1. Accuracy @ V<sub>PN<\/sub>,T<sub>A<\/sub>=+25\u2103:\u00b11%<\/p><p>\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 T<sub>A<\/sub>=-25\u2103~+70\u2103 :\u00b13%<\/p><p>2. Non-linearity @ V<sub>PN<\/sub>, T<sub>A<\/sub>=+25<sup>\u00a0o<\/sup>C: better than +\/-0.1%<\/p><p>3. Offset voltage @ V<sub>P<\/sub>=0, T<sub>A<\/sub>=+25<sup>\u00a0o<\/sup>C: not more than +\/-35mV<\/p><p>@ V<sub>P<\/sub>=0, T<sub>A<\/sub>=-25<sup>\u00a0o<\/sup>C~+70<sup>\u00a0o<\/sup>C: not more than +\/-100mV<\/p><p>4. Response time @90% of V<sub>Pmax<\/sub>: not more than 4us<\/p><p>5. Frequency bandwidth (-3dB): DC 15kHz<\/p><p><strong>General data:<\/strong><\/p><p>1. Operating temperature: -25\u00baC~+70\u00baC<\/p><p>2. Storage temperature: -40<sup>\u00a0o<\/sup>C ~+85<sup>\u00a0o<\/sup>C<\/p><p>3. Total primary power loss: 2W<\/p><p>4. Primary resistance @ T<sub>A<\/sub>=+25<sup>\u00a0o<\/sup>C: 245 kilohm<\/p><p>5. Weight: 300g<\/p><p>6. Standards: EN 50155<\/p><p><strong>Features:<\/strong><\/p><p>1. Close loop (compensated) voltage transducer<\/p><p>2. Galvanic isolation between primary and secondary circuit<\/p><p>3. Insulated plastic case made of black PC recognized according to UL 94-V0<\/p><p><strong>Dimension:<br \/><img decoding=\"async\" src=\"http:\/\/img.hisupplier.com\/var\/userImages\/2012-09%2F27%2F154835418114.jpg\" alt=\"\" align=\"absMiddle\" \/><br \/><\/strong><\/p><p><strong>Connection:<br \/><img decoding=\"async\" src=\"http:\/\/img.hisupplier.com\/var\/userImages\/2012-09%2F27%2F154850801919.jpg\" alt=\"\" align=\"absMiddle\" \/><\/strong><\/p><\/div><p><br \/><br \/><\/p>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<table>\n<tbody>\n<tr>\n<td><span style=\"font-weight: 400;\">Model No.<\/span><\/td>\n<td><span style=\"font-weight: 400;\">NCV1-1000V\/SP1<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Usage<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Level Sensor<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Output<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Switching Transducer<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Brand Name<\/span><\/td>\n<td><span style=\"font-weight: 400;\">CSR<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Theory<\/span><\/td>\n<td><span style=\"font-weight: 400;\">Hall Sensor<\/span><\/td>\n<\/tr>\n<tr>\n<td><span style=\"font-weight: 400;\">Primary nominal voltage<\/span><\/td>\n<td><span style=\"font-weight: 400;\">1000V<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n","protected":false},"featured_media":10195,"template":"","meta":[],"product_cat":[164],"product_tag":[177],"class_list":{"0":"post-10486","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-164","7":"product_tag-crrc-hy","8":"pa_brand-crrc-hy","10":"first","11":"instock","12":"shipping-taxable","13":"product-type-simple"},"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/amengineering.am\/hy\/wp-json\/wp\/v2\/product\/10486","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/amengineering.am\/hy\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/amengineering.am\/hy\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":1,"href":"https:\/\/amengineering.am\/hy\/wp-json\/wp\/v2\/product\/10486\/revisions"}],"predecessor-version":[{"id":10488,"href":"https:\/\/amengineering.am\/hy\/wp-json\/wp\/v2\/product\/10486\/revisions\/10488"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/amengineering.am\/hy\/wp-json\/wp\/v2\/media\/10195"}],"wp:attachment":[{"href":"https:\/\/amengineering.am\/hy\/wp-json\/wp\/v2\/media?parent=10486"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/amengineering.am\/hy\/wp-json\/wp\/v2\/product_cat?post=10486"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/amengineering.am\/hy\/wp-json\/wp\/v2\/product_tag?post=10486"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}